Start typing and press Enter to search

Sale!

Fluke 54-2 B 60HZ Dual-Input Digital Thermometer with Data Logging, 60 Hertz Noise Rejection

$149.00 $695.78
Review

INCLUDES: (1) Digital Thermometer (1) Impact Absorbing Holster (2) Beaded Probe ThermocouplesFEATURES: Relative time clock on MIN/MAX/AVG provides time reference for major events Electronic Offset function allows compensation of thermocouple errors to maxi



SKU: JK6447246520 Category:

INCLUDES:
(1) Digital Thermometer
(1) Impact Absorbing Holster
(2) Beaded Probe Thermocouples

FEATURES:
Relative time clock on MIN/MAX/AVG provides time reference for major events
Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
Measures J, K, T, R, S, N and E-type, for a total of 7 thermocouple types
Readout in C, F, or Kelvin (K)
Splash and dust resistant case protected by impact absorbing holster
User-friendly front panel is easy to set up and operate
Sleep mode increases battery life; typical 1000-hour battery life
Battery door allows easy battery replacement without breaking the calibration seal
Large backlit dual display shows any combination of T1, T2, T1-T2, plus MIN/MAX/AVG
Recall function allows logged data to be easily reviewed on meter display
Infrared USB communication port allows data to be exported to optional FlukeView Forms Temperature PC software for further analysis and graphing
Data Logging up to 500 points of data with user-adjustable recording intervals

SPECIFICATIONS:
Measurement Accuracy Above -100 C (-148 F): J, K, T, E, and N-type: [0.05% + 0.3C (0.5F)]*, R and S-type: [0.05% + 0.4C (0.7F)]*
Measurement Accuracy Below -100 C (-148 F): J, K, E, and N-types: [0.20% + 0.3C (0.5F)]*, T-type: [0.50% + 0.3C (0.5F)]
Display Resolution: 0.1C / F / K < 1000, 1C / F / K 1000
Measurement Range: J-Type -210C to 1200C (-346F to 2192F), K-Type -200C to 1372C (-328F to 2501F), T-Type -250C to 400C (-418F to 752F), E-Type -150C to 1000C (-238F to 1832F), N-Type -200C to 1300C (-328F to 2372F)*, R and S-Type 0C to 1767C (32F to 3212F)*
Temperature Scale: ITS-90
Applicable Standards: NIST-175
Operating Temperature: -10C to 50C (14F to 122F)
Storage Temperature: -40C to 60C (-40F to 140F)
Humidity: 0% to 90%; 0C to 35C (32F to 95F), 0% to 70%; 0C to 50C (32F to 122F)
Battery: 3 AA Batteries; Typical 1000-hour Life
Safety: CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2

Laboratory accuracy. Wherever you go. The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05 + 0.3degrees Celsius) in a rugged, handheld test tool. Dual input thermometer with USB recording 60 HZ noise reduction.

Reviews

There are no reviews yet.

Be the first to review “Fluke 54-2 B 60HZ Dual-Input Digital Thermometer with Data Logging, 60 Hertz Noise Rejection”

Your email address will not be published. Required fields are marked *